Application: |
|
The clinical electrophysiologic testing of vision is intended for objective assessment of visual pathway starting from retina to cortex: |
• |
electroretinography (ERG) — recording of electrical activity of retina (electroretinogram) generated in response to the light stimulus; |
• |
visual evoked potentials (VEP) — study of the electrophysiological signals extracted from the electroencephalographic activity in the visual cortex recorded from the overlying scalp; |
• |
electro-oculography (EOG) — recording of changes in electrical potential across the retinal pigment epithelium recorded during successive periods of light and dark adaptations. |
|
|
|
These tests allow: |
• |
diagnosing the disorders of retina and optic nerve at early stages; |
• |
diagnosing the congenital blindness in infants within first few months; |
• |
studying the retina at different disorders: perform diagnostics, make prognosis and control |
|
the pathological processes in it; |
• |
estimating the degree of visual function impairment at visual cortex level; |
|
assessing the reversibility of changes in visual pathway required to perform target treatment. |
|
|
|
Neuro-ERG digital ERG system allows performing the following tests: |
• |
rod ERG; |
• |
maximal ERG; |
• |
cone ERG; |
• |
pattern ERG (PERG); |
• |
focal ERG; |
• |
flicker ERG; |
• |
оn/оff ERG; |
• |
oscillatory potentials; |
• |
multifocal ERG; |
• |
flash or pattern-reversal VEP; |
• |
steady-state VEP; |
• |
electro-oculography. |
|
|
|
Robust Amplifier and Stimulator with Advanced Parameters |
|
The high sampling rate and A/D converter resolution, wide bandpass and up to 100 Hz stimulation frequency allow obtaining the traces of premium quality. |
|
|
|
Mini-ganzfeld Stimulator and Penlights with Concentrators |
|
The mini-ganzfeld stimulator intended to perform the main tests (cone ERG, rod ERG, flicker ERG, oscillatory potentials) complies with the ISCEV standard requirements. |
|
Such tests as focal ERG or cone ERG elicited by different colour flash stimuli are done with penlights with concentrators (red, blue, green, white). They are fixed on a special holder ensuring secure stimulator fixation near the pupil. |
|
|
|
Set of Specially Designed Electrodes |
|
The set of ERG electrodes specially designed with the assistance of A.M. Shamshinova (Helmholtz Moscow Research Institute of Eye Diseases, Russia) is supplied with the device. |
|
The electrodes are constructed in the form of small “hooks” and “loops”. The electrodes of such shape do not cause the unpleasant feelings in a patient during the test and are very convenient for use in comparison with the contact-lens electrodes. |